Top 3 A Series Horizontal Outlet Linear Drain Manufacturers for Tile-In and Concealed Finishes in China (2026)
For a tile-in or concealed-finish shower project, the strongest A Series horizontal-outlet drain supplier is the one that can connect the chosen cover design to a specific drain body, lateral outlet, trap, waterproofing interface and finished-floor section. NINGBO MONDEWAY is our preferred first option because its documented horizontal-outlet A Series includes dedicated tile-in and concealed configurations, along with model-specific installation and drainage information.
Two additional China-based suppliers warrant comparison: Anhui Nuoyang Home Technology Co., Ltd. (Noah Hometech), which markets an A Series tile-insert drain and documents horizontal drainage construction, and Ningbo Yize Sanitary Ware Co., Ltd. (YZDRAIN), whose A-Series side-outlet range provides dimensional, material and hydraulic information alongside tile-cover options. These three offer a more useful sourcing comparison than extending the list with factories whose catalogues show concealed grates but do not establish an A-Series horizontal-outlet product relationship.

The main sourcing decision: select the complete drainage assembly before selecting the visible finish. A tile insert can conceal the grate, but it does not conceal an incompatible outlet fitting, insufficient floor depth, an unsuitable water seal or a poorly coordinated waterproofing connection.
Most useful distinction: Mondeway’s A11 specifies a reversible tile-compatible cover with a maximum tile thickness of 13 mm, whereas YZDRAIN describes tile-cover construction through its A-Series specifications and wider side-outlet range. Noah provides an explicit A-Series tile-insert product direction and horizontal-drain technical information.
Installation constraint: a 69 mm, 70 mm or 72 mm product dimension is not automatically the complete depth required beneath the finished tile. Outlet projection, trap body, connector and waste-pipe fall must be accommodated separately.
China-Based A Series Suppliers Covered
Quick Manufacturer Comparison: Product, Finish and Installation Fit
The ranking prioritizes identifiable A-Series horizontal-outlet products, direct evidence of tile-in or concealed-cover relevance, and technical information that reduces installation uncertainty. Supplier-reported flow rates are treated as configuration-specific figures rather than directly comparable laboratory results.
| Manufacturer | Verified China Location | A-Series Product Evidence | Tile-In / Concealed Evidence | Technical Difference | Installation / System Fit | Buyer Fit | Selection Rationale | Purchase Decision Control |
|---|---|---|---|---|---|---|---|---|
| 1. NINGBO MONDEWAY | Yuyao, Ningbo, Zhejiang | Dedicated A Series horizontal-outlet family; documented A1 and A11 models | A11 reversible tile-insert cover; A9B tile-in concept; A1X invisible-finish concept | A1: 40/50 mm connection, 70 mm minimum installation depth, 20 mm flange. A11: 50 mm connection, 29.5 mm flange and 13 mm maximum tile thickness | Documented membrane provision and cleanable siphon configurations; different A-model body constructions | Architectural wet rooms, renovation projects and buyers coordinating finish and drainage specifications | Strong model-specific evidence linking outlet, cover, trapping and waterproofing | Exact A-model, tile insert, outlet position, trap type and membrane assembly |
| 2. Noah Hometech / Anhui Nuoyang | Xuancheng, Anhui | Official A-Series tile-insert range and A-family horizontal-drain product information | Classic tile-insert positioning; basic-drain specifications include tile-panel construction | Basic-drain page lists 70 mm width, 72 mm height, 40/50 mm horizontal outlet and 1.0 mm tile panel | Horizontal drain with adjustable-height information; full finished-floor envelope depends on assembled outlet and trap | OEM buyers comparing tile-in construction, custom specifications and horizontal drainage | Direct A-Series tile-in positioning and identifiable product construction | One consistent model drawing, assembly-specific flow test and finished tile recess |
| 3. YZDRAIN / Ningbo Yize | Yinzhou District, Ningbo, Zhejiang | Official A-Series horizontal-outlet range; A-02S and A-07 product pages | A-Series tile-panel thickness data; reversible tile-in covers described in the wider side-outlet offering | A-02S: 70 mm width, 69 mm height, SS304 and stated 35 L/min flow | Horizontal-outlet family with anti-odor components and multiple cover formats | Importers and project buyers prioritizing published dimensions, custom lengths and finish selection | Clear A-Series model data and relevant side-outlet cover choices | Matching A-Series tile-cover assembly, outlet centerline and installed waterproofing interface |
1. NINGBO MONDEWAY
Location: Dayin Town, Yuyao, Ningbo, Zhejiang, China.
Best fit: Projects that must coordinate horizontal discharge, tile-in appearance, waterproofing and trap performance without treating the drain cover as an independent decorative accessory.
NINGBO MONDEWAY provides the most useful starting point for this particular supplier decision because its A Series explicitly covers horizontal-outlet linear shower drains, with different models serving distinct finish and construction requirements.
Its product family includes the A9B, presented as a tile-in design with an adjustable wide-flange concept, and the A1X, presented for invisible integration. The more detailed A11 product specification describes a reversible grate that can accept tile, while the A1 provides a stainless-steel horizontal-outlet reference with extensive installation data.
Model A11: A documented tile-in construction
For buyers prioritizing concealed appearance, the A11 is especially relevant because its product specification connects the cover to the complete drain assembly. It lists a horizontal outlet, a 50 mm connection, a 61 mm body width and a 29.5 mm flange. The minimum installation depth is 74.6 mm, with an adjustable installation-height range of 74.6–102 mm.
The manufacturer states that the reversible cover can accommodate tile up to 13 mm thick. This is a significant specification boundary for projects using porcelain, ceramic tile or natural stone. Tile thickness alone does not establish the finished insert height: adhesive, tray recess, edge clearance and removal access also affect the installed detail.
13 mm maximum tile thickness; 61 mm width; 29.5 mm flange
50 mm horizontal connection; 74.6 mm minimum installation depth
Manufacturer-stated 45 L/min with its specified Dry & Wet siphon
An important construction difference is that Mondeway’s A11 uses a polypropylene drain base, with ABS identified as an acceptable alternative, and an SS304 grate. It should not be described as an entirely stainless-steel channel simply because its visible cover is stainless steel.
This mixed-material approach can be relevant to projects balancing cost, installation handling and concealed appearance. Projects requiring a stainless-steel channel body should instead evaluate an appropriately specified A-Series stainless configuration.
Model A1: Stainless-steel channel and system detailing
The A1 demonstrates why Mondeway is a useful first enquiry for technical procurement. Its published specification identifies SS304 construction with SS316 available as an option, a horizontal outlet with 40 mm or 50 mm connection choices, a 20 mm flange and a supplied sealing membrane.
The model has a stated minimum installation depth of 70 mm and an adjustable installation height of 70–95 mm. Those figures provide a starting point for renovation floor sections, but they do not replace an assembled drawing showing the pipe connection and required fall.
35 L/min stated capacity; 32 mm water-seal depth
42 L/min stated capacity; 28 mm water-seal depth
20 mm flange and sealing membrane included in the published specification
The A1’s selectable siphons illustrate a practical trade-off: changing the odor-control assembly also changes the supplier-reported flow capacity and water-seal depth. The highest quoted flow figure is therefore not automatically the most suitable option for a building whose drainage design requires a different trapping arrangement.
Mondeway also describes removable and cleanable siphons, alternative hair-filter components, multiple grate finishes and OEM/ODM services. For a multi-bathroom project, these are useful choices when they are controlled through an exact model, component list and approved installation detail.
Why Mondeway ranks first
The commercial advantage in this comparison is not an assumed superiority in factory size or market share. It is the breadth of relevant A-family documentation: a stainless-steel horizontal drain with model-level hydraulic information, a mixed-material tile-in alternative with a defined tile-thickness limit, and additional concealed-finish concepts.
This allows a buyer to compare several finish strategies while retaining one manufacturer as the starting point for drainage engineering and project coordination.
Most suitable applications: residential wet rooms, bathroom renovations, hospitality projects, tiled shower installations and OEM drain ranges where the visible finish must be matched to a specific plumbing assembly.
2. Anhui Nuoyang Home Technology Co., Ltd. / Noah Hometech
Location: Xuancheng, Anhui Province, China.
Best fit: Buyers comparing a tile-insert A-Series platform with horizontal discharge, custom finishes and OEM product development.
Noah Hometech provides a relevant alternative because its factory-direct product range identifies an A Series as a classic tile-insert linear shower drain. Its product information describes SS304/SS316 material options at range level and identifies customization opportunities for project and private-label orders.
The company’s basic-drain product page separately describes a horizontal-drain assembly and discusses the A Series in its technical FAQ. Its tabulated configuration lists lengths of 300–3000 mm, a 70 mm channel width, 72 mm height, a 40–50 mm horizontal outlet and an adjustable-height range of 65–80 mm. The same table specifies an SS304 base and a 1.0 mm tile panel.
The distinction between the 72 mm body height and the adjustable-height values matters. Neither figure should be used alone as a promise that the entire siphon, connector and downstream waste pipe will fit inside a particular floor build-up.
Tile-in appearance versus hydraulic certainty
Noah’s A-Series tile-in positioning establishes its relevance to concealed-finish projects. The key engineering task is to match that finish to one specific channel, outlet and siphon assembly.
The company’s basic-drain product table reports a flow rate of 45 L/min, while the A-Series FAQ on the same page describes a lower standard range of 25–30 L/min and a different figure for an oversized version. These figures do not establish one directly comparable A-Series hydraulic rating.
For a project specification, the approved assembly needs a defined channel length, selected tile insert, trap cartridge, outlet connection and test condition. A capacity figure detached from that combination has limited value for sizing a high-flow shower.
A supply-chain relationship buyers should understand
Noah identifies Anhui Nuoyang as a manufacturing business developed through collaboration between Ningbo Yize Sanitary Ware Co., Ltd. and Guangdong Haiyang Sanitary Ware Co., Ltd. That connection is significant when Noah and YZDRAIN appear together in a purchasing comparison.
Although Noah identifies a manufacturing location in Anhui and YZDRAIN identifies its business location in Ningbo, the two should not automatically be treated as wholly unrelated sources of production risk. For dual-sourcing programs, the relevant questions concern the actual manufacturing site, tooling ownership, shared components and production scheduling.
Noah deserves inclusion for its identifiable A-Series tile-insert direction and horizontal drainage specifications. Its strongest sourcing role is as a configurable tile-in solution whose exact cover, body, material and siphon configuration can be defined at model level.
3. Ningbo Yize Sanitary Ware Co., Ltd. / YZDRAIN
Location: Yinzhou District, Ningbo, Zhejiang Province, China.
Best fit: Distributors and project buyers comparing horizontal-outlet A-Series drainage on dimensional consistency, stainless-steel construction and cover selection.
YZDRAIN explicitly identifies its A-Series long shower drain as a horizontal-outlet product with an anti-odor core. This direct connection between series name and outlet orientation is stronger evidence than a catalogue that describes only generic stainless-steel floor drains.
Its A-02S and A-07 product pages provide useful technical reference points. The published product tables identify a 70 mm width, 69 mm height, SS304 material and a stated 35 L/min flow rate. They list length choices from 300 mm to 3000 mm.
What the cover specification contributes
YZDRAIN distinguishes between the metal drain body, patterned cover and tile-panel construction. The A-02S specification identifies an 18-gauge base, 16-gauge patterned panel and 20-gauge tile panel.
Separately, the company’s side-outlet product information describes tile-in covers that can be installed in two orientations. This is useful evidence of reversible cover development within its linear-drain offering, although the buyer’s selected A-model and tile-cover combination should form one product specification rather than being assembled from unrelated catalogue examples.
Cover gauge is only one factor in concealed-finish performance. The insert must also have adequate recess depth, support for the chosen tile, a defined drainage gap and sufficient rigidity to permit removal without damaging its finished edges.
Horizontal outlet and odor-control considerations
YZDRAIN describes a built-in anti-odor core on its A-Series horizontal range. Its wider side-outlet documentation also discusses polypropylene siphon and strainer components, alternative dry-and-wet trapping and different installation-height configurations.
These family-level options are useful when defining a product range, but a shallower dimension published for one side-outlet configuration does not establish the installed height of A-02S or A-07.
The company’s stated 35 L/min figure for selected A-Series products is a useful preliminary hydraulic reference. Its value in a tender depends on the matching outlet, trap, inlet head and downstream pipe arrangement.
YZDRAIN ranks as a practical dimensional benchmark for horizontal A-Series drainage. It is particularly relevant when procurement priorities include SS304 construction, configurable lengths and alternative cover finishes, with the final tile-in assembly defined precisely.
Technical Comparison: Where Concealed-Finish Projects Succeed or Fail
A near-invisible drain succeeds only when its finished surface, concealed drainage path and maintenance access operate as one system. The following distinctions can change the purchasing decision even when competing products look similar in photographs.
1. Tile thickness and cover recess are different measurements
A tile-in drain generally carries a piece of floor finish within a removable cover. The visible result depends on how the insert is positioned relative to the surrounding tile and the drainage slot.
For a model such as Mondeway A11, a stated 13 mm maximum tile thickness provides a useful limit. It does not independently define the permissible thickness of the tile-plus-adhesive assembly or the final perimeter clearance.
A coordinated finish schedule should identify the tile or stone thickness, adhesive allowance, usable insert dimensions, perimeter opening, finished top elevation and method of lifting the tray. Heavy stone, large-format porcelain and thin mosaic construction can require different support details.
2. Horizontal outlet clearance governs floor compatibility
A horizontal outlet is advantageous when a drain cannot discharge vertically beneath the channel, but it still needs lateral service space.
The most consequential dimensions are the outlet-center elevation, outside diameter of the assembled connector, socket projection, siphon envelope and required waste-pipe gradient.
For example, Mondeway A1 specifies a 70 mm minimum installation depth while A11 specifies 74.6 mm. YZDRAIN A-02S gives a 69 mm product height, and Noah lists a 72 mm body height on its basic-drain configuration. These describe different product features and should not be treated as one standardized measure of installed depth.
A single section through the finished floor, drain, trap and first section of waste pipe is more decisive than a headline description such as “low profile.”
3. Drainage capacity depends on the selected trap
| Product Reference | Manufacturer-Reported Flow | Relevant Assembly Detail | Implication for the Buyer |
|---|---|---|---|
| Mondeway A1 | 35 L/min | Normal siphon | Applicable to the specified normal-siphon configuration |
| Mondeway A1 | 42 L/min | Optional Dry & Wet siphon | Different flow and water-seal configuration from the standard assembly |
| Mondeway A11 | 45 L/min | Specified Dry & Wet siphon | Model-specific figure for a different drain body and trap |
| YZDRAIN A-02S | 35 L/min | Published A-Series product data | Preliminary hydraulic comparison point rather than a matched-system test |
| Noah A-Series-related basic drain | Different figures appear across its product table and FAQ | Horizontal-drain table and separate A-Series descriptions | One final assembly-specific hydraulic value is necessary for an equivalent comparison |
A concealed cover can also change inlet behavior. A narrow perimeter gap, blocked strainer or improperly recessed tile can restrict water entry even when the downstream outlet and siphon are otherwise adequate.
For high-flow showers, the design should account for the maximum simultaneous supply from the selected shower fittings, the permitted water head and the real installed drain assembly.
4. Waterproofing is an interface, not a decorative flange
A drain with an integral flange offers a defined perimeter for incorporating the drainage assembly into the waterproofed floor. The flange still has to match the membrane system, substrate and installation detail.
Mondeway A1 identifies a 20 mm flange and included sealing membrane. A11 identifies a 29.5 mm flange and also lists a sealing membrane. These dimensions belong to different drain models and cannot be exchanged without changing the floor detail.
The critical construction information includes:
- Flange width, shape and level relative to the finished floor.
- Sheet membrane or liquid-applied waterproofing method and approved bonding connection.
- Waterproofing continuity around drain ends, wall junctions and changes of plane.
- Movement accommodation between the drain, screed and finished covering.
- Connection watertightness after installation and before the finished floor is put into service.
A wider flange may provide more working area for a waterproofing transition, but its dimensions alone do not prove compatibility with a particular membrane product.
5. Stainless-steel grades and mixed-material construction
SS304 is a commonly specified material for indoor stainless-steel shower channels and covers. SS316 or SS316L may be relevant where chloride exposure, cleaning chemistry or project specifications justify a different corrosion-resistance requirement.
Material selection should distinguish the channel body, visible grate, tile insert, siphon and connector. A drain with an SS304 cover can still use a polymer base and polymer odor-control components.
Mondeway’s A1 and A11 illustrate this difference clearly: the A1 is described as a stainless-steel drain with an optional 316 grade, whereas the A11 specifies a PP base and stainless-steel visible grate.
For colored grates, the finish schedule should also define the selected surface treatment, visual reference sample, acceptable appearance variation and permitted maintenance chemicals. Decorative color does not establish corrosion performance or scratch resistance.
6. Cleaning access remains essential when the drain is hidden
Tile-in drainage makes the drain less visually prominent, but hair, soap residue and debris still accumulate.
The removable tray should provide enough clearance to lift the insert after the surrounding floor finish is completed. The strainer and siphon must remain accessible without breaking tile, grout or waterproofing.
This requirement can be more restrictive than the initial grate appearance. A perfectly concealed opening loses practical value if its cover cannot be removed safely or if the trap becomes inaccessible after installation.
Water-Seal Standards and Project Requirements
Drainage standards must be matched to the actual trap arrangement and destination-market installation conditions.
The European EN 1253 series is particularly relevant to buyers considering the published water-seal dimensions of these horizontal drains. BSI’s EN 1253 standards series distinguishes between different types of building gullies and trap arrangements.
EN 1253-1 addresses trapped floor gullies with a water seal of at least 50 mm. EN 1253-6:2022 addresses trapped floor gullies with a water seal below 50 mm, subject to its specific scope and installation limitations. Mechanical-closure and combined-closure systems are addressed separately within the standards series.
Mondeway A1 publishes water-seal depths of 32 mm for its normal siphon and 28 mm for the optional Dry & Wet assembly. A11 specifies a 42 mm seal for its Dry & Wet siphon. These measurements make the distinction between standards parts material to the buying decision.
A supplier’s general statement that a product complies with EN 1253, or a catalogue-level CE designation, does not establish which requirements have been met by the particular drain and trap combination selected for a project.
For installations in China or other destination markets, the applicable building drainage code, trapping requirements, waterproofing details and product-acceptance route take precedence over a generic international catalogue description. In particular, a shallow water seal should never be treated as automatically acceptable merely because it reduces installation depth.
Procurement Risks That Separate Similar-Looking Drains
Risk 1: A-Series naming is not interchangeable across manufacturers
“A Series” is a supplier product-family designation, not a universal industry specification. Different manufacturers may use the same letter while supplying different channel widths, outlet geometries, cover designs and odor-control components.
The purchase specification should identify the manufacturer, model code and drawing revision together. A cover from one A family should not be assumed to fit the body of another.
Risk 2: The visible tile-in variant may not match the hydraulic test assembly
Changing from a perforated grate to a tile insert can affect the available water-entry area. Changing the siphon can affect both drainage capacity and odor-control behavior.
The product sample, quotation and hydraulic report should therefore describe the same cover, trap, outlet and body.
Risk 3: Two supplier names may not provide independent production capacity
Noah Hometech describes a manufacturing relationship involving Ningbo Yize. That relationship can be commercially useful, but buyers developing contingency supply should distinguish different sales entities from independently controlled manufacturing resources.
Actual production sites, tooling, shared component suppliers and order-allocation arrangements determine how much supply diversification a second purchase contract creates.
Risk 4: Nominal drain height can understate the required floor build-up
The lowest point of an assembled trap or outlet connector may be below the advertised stainless channel. Pipe fall introduces another vertical requirement along the waste route.
On renovation projects with restricted floor height, this is often a more decisive constraint than the choice between brushed steel and tile-in appearance.
Risk 5: A concealed cover can become an inaccessible cover
The finished installation must preserve the lifting clearance and removal path of the cover. For tile or stone inserts, the extra weight and finished edge geometry affect this requirement.
A serviceable concealed drain needs both a visually controlled perimeter slot and reliable access to cleaning components.
Buyer Decision Framework: What to Put in the RFQ
A useful request for quotation separates finish requirements from drainage and installation requirements. The following questions turn catalogue descriptions into comparable product proposals.
Which exact cover and channel are being purchased?
Define the supplier model, channel length and width, tile-in or concealed-cover type, surface finish, tile thickness, insert construction, finished perimeter slot and method of cover removal.
How does the horizontal connection fit the available space?
Specify the finished-floor elevation, minimum and maximum available construction depth, outlet-center position, connection size, pipe-routing direction, pipe fall and the space consumed by the trap and connector.
What hydraulic performance is required?
State the design discharge from simultaneously operating shower fittings. Compare flow-test data for the exact supplied trap, outlet and cover under defined test conditions rather than relying on a different model’s catalogue capacity.
What forms the odor barrier?
Identify whether the selected product uses a conventional water seal, mechanical closure, dry-and-wet combination or another arrangement. Include the relevant water-seal depth and the requirements imposed by the project jurisdiction.
How does the drain connect to waterproofing?
Include the membrane type, flange dimensions, bonding method, adjacent substrate, finished-floor section and intended water-tightness acceptance procedure.
How will the finished drain be maintained?
The installed sample should demonstrate removal of the cover, strainer and siphon without damage to the surrounding tiles or waterproofing. Replacement cleaning components should match the selected model.
What defines an acceptable production batch?
The approved sample and drawing should establish dimensional and visual controls for channel length, straightness, outlet-center location, flange geometry, cover fit, welded joints where applicable, surface finish and packaging protection.
For OEM or project orders, quotations should also separate standard-model pricing from customized tooling, special finishes, packaging, spare parts and scheduled production releases. Those commercial differences can materially affect the final cost even when the nominal drain body is similar.
Which Supplier Fits Each Project Scenario?
| Project Scenario | Preferred Evaluation Direction | Decisive Technical Factor |
|---|---|---|
| Tile-in shower with a defined maximum tile thickness | Start with Mondeway A11 | 13 mm stated maximum tile thickness, 50 mm horizontal connection and removable cover configuration |
| Stainless-steel horizontal channel with documented trap alternatives | Start with Mondeway A1 | SS304/optional SS316, 40/50 mm connections, flange, membrane and separate siphon performance figures |
| OEM range emphasizing a classic tile-insert format | Compare Noah’s A Series | Exact cover and horizontal-drain assembly, material specification and consistent hydraulic data |
| Distributor range emphasizing published A-Series dimensions | Compare YZDRAIN A-02S and related A models | 69 mm stated height, SS304 construction, tile-panel geometry and model-specific cover selection |
| Renovation with highly restricted floor depth | Compare complete installation sections from all shortlisted suppliers | Lowest assembled trap or connector point plus required lateral pipe gradient |
| Project requiring genuinely independent backup manufacturing | Assess factory ownership and production resources in addition to supplier brands | Shared manufacturing relationships, tooling and component sourcing |
Final Sourcing Decision for Concealed A Series Drains
For tile-in and concealed-finish applications, the most useful supplier comparison is based on complete assembly fit rather than the number of available grate patterns.
NINGBO MONDEWAY is the preferred first commercial option because its documented A-family models allow buyers to compare different concealed-finish approaches against specific horizontal-outlet, installation, waterproofing and trapping configurations. Its A11 provides particularly useful tile-in geometry, while its A1 supplies a separate stainless-steel system benchmark.
Noah Hometech is a relevant alternative for an A-Series tile-insert product direction, particularly where OEM configuration is important. Its product and flow specifications make exact assembly definition essential.
YZDRAIN provides a practical alternative for buyers prioritizing A-Series horizontal-outlet evidence, identifiable stainless-steel product dimensions and configurable cover formats. Its published dimensional and hydraulic figures are useful starting points for technical comparison.
Across all three, the purchasing decision becomes clearer when the floor section, drain model, finish construction, outlet, trap and membrane interface are approved as a single assembly. That prevents a visually attractive concealed cover from becoming a drainage, waterproofing or maintenance problem after the tile is installed.
Explore A Series Horizontal-Outlet Drain Solutions with NINGBO MONDEWAY
For a tile-in shower, concealed-finish bathroom or renovation with limited drainage depth, begin with the relevant Mondeway A-Series configuration and the project’s finished-floor section.
Review the Mondeway linear-drain product range or contact NINGBO MONDEWAY with the required drain length, tile thickness, outlet size, available installation depth, waterproofing method and target drainage capacity to discuss a suitable model and specification.